Serratus Anterior Plane Block Ultrasound Phantom

Overview
This guide describes how to build a layered ballistic gelatin phantom for simulating the serratus anterior plane block. The model uses viral probe covers filled with psyllium-enhanced gelatin and cut syringe halves to replicate the rib cage, intercostal muscles, and fascial planes between the serratus anterior and latissimus dorsi. IV tubing filled with saline simulates the thoracodorsal artery, allowing trainees to practice in-plane needle guidance, fascial plane identification, and hydrodissection.
Materials
- Water (~405 mL)
- Ballistic gelatin powder (~45g; e.g., Rooted in Rare, 529 Commerce LLC, Parkland, FL; 10% solution)
- Psyllium powder (2.25g)
- Sodium metabisulfite (1/4 tsp, ~1.5g)
- Viral probe covers x3 (Sheathes 3D™ Seamless Viral Barrier Box End, Latex-Free, Polyurethane, 1" x 3" Face to 4.5" x 12"L, Sheathing Technologies Inc., Morgan Hill, CA)
- 30 mL syringe x2
- Trauma shears or heavy-duty scissors
- Super glue
- Kidney basins x4
- Normal saline flushes (multiple)
- Ultrasound gel
- Short IV extension tubing x2
- Spinal needle
- Towel or chuck pad (recommended for use during simulation)
Steps
Prepare Ballistic Gelatin Solution
Prepare 450 mL of ballistic gelatin solution. We created a 10% concentration by slowly stirring 45g of our ballistic gelatin powder into 405 mL of water heated to 140°F (60°C). Stir slowly to avoid introducing air bubbles.
Add Psyllium and Preservative
As the gel solution cools, add 2.25g of psyllium powder (0.5% by weight) to achieve the desired ultrasound echogenicity. Then add 1/4 tsp (approximately 1.5g) of sodium metabisulfite to act as a fungal growth retardant. Stir to combine.
Fill Probe Covers with Gel
In each of three kidney basins, lay a viral probe cover flat across the bottom. Using a 30 mL syringe to avoid spills, slowly introduce 100 mL of gel solution into the first probe cover, 150 mL into the second, and 200 mL into the third, allowing the gel to form a flat, pancake-like layer in each. After filling each cover, gently remove air from the closed end toward the open end, then tie the open end shut.

Prepare Syringe Rib Simulators
Using trauma shears or heavy-duty scissors, cut both 30 mL syringes in half lengthwise. Then cut the syringe halves to a size that will fit inside the kidney basins. These cut syringe halves will simulate hyperechoic ribs embedded within intercostal muscle layers.

Attach Rib Simulators to Gel Layer
Use super glue to attach three or four of the cut syringe halves to the outer surface of the probe cover containing 200 mL of gel. Position them to simulate the appearance of hyperechoic ribs within a layer of intercostal muscles, located below the serratus anterior.

Stack Basins and Refrigerate
Place another kidney basin on top of the syringe halves attached to the 200 mL probe cover. Flip the two basins upside down together to hold the syringe halves in place. Place all basins in the refrigerator and allow the gelatin to set per manufacturer recommendations — in this case, approximately 36 hours.

Assemble Layered Phantom
After the full setting time, remove the three solidified gel-filled probe covers from the refrigerator. Place the 200 mL layer (with embedded rib simulators) on the bottom. Apply a generous layer of ultrasound gel on top of it, then place a short piece of IV extension tubing connected to a saline flush on top of that ultrasound gel layer — this simulates the fascial plane between the serratus anterior and latissimus dorsi, with the IV tubing representing the thoracodorsal artery. Place the 150 mL probe cover on top of the tubing, apply another layer of ultrasound gel, and then place the 100 mL probe cover on top to simulate the subcutaneous tissue to complete the layered structure.

Simulate Thoracodorsal Artery Flow
Place the assembled model on a towel or chuck pad to absorb saline leakage. To simulate blood flow through the thoracodorsal artery, place a color Doppler box over the short IV tubing and inject quick, short bursts of saline into the connected flush. The flow artifact visible on Doppler confirms the simulated vessel location.

Set Up Block Needle
Connect a saline flush to a short piece of IV extension tubing. Remove the stylet from a spinal needle and connect the needle to the IV tubing. Prime the entire line with saline to ensure it is ready for injection during the procedure simulation.
Practice In-Plane Needle Guidance
Using an in-plane ultrasound approach, guide the primed spinal needle toward the fascial space between the latissimus dorsi and serratus anterior layers. Have an assistant inject saline to hydrodissect once the needle tip appears to be in the correct plane. Confirm correct placement by observing saline leak between the probe cover layers — if saline does not leak out between layers, the needle is likely within a muscle layer rather than the fascial plane. Optionally, add food coloring to the saline for enhanced visual confirmation of injection spread.
Photo 1 of 3
Source
Dr. Charles Jang.
Published here by the author.